Contraception in compare.



Contraception with Lady-Comp or Baby-Comp is easy, health and very safe.
Please compare
:


Contraception in comparison:

Effect

Pros

Cons

Lady-Comp (Pearl-lndex 0.7):
30 seconds a day (after waking) measured by sensor under the tongue. Pressing a key once, display indicates : "green" = infertile, "red" = fertile. All data for exact identification of ovulation are programmed

Natural, extremely safe, ecologically beneficial and healthy contraception. No harm to your body by chemistry. Single investment without recurring cost.

On request, the appliance can be fitted with a planning program.

 

There are only few fertile days on which either continence or use of condoms are required.

Baby-Comp (Pearl-lndex 0.,7):
Like Lady-Comp, with integrated special program for planning a wanted child
   
Pill (Pearl-lndex 0,1-0,9):
There are about 100 different kinds. The body is supplied with dosed hormones (oestrogen and progestogen) simulating pregnancy.
Due to the sudden break in hormone supply the menstruation starts during the break.

Very safe.

Serious side effects of various grades. Higher risk for smoking and drinking women. Unilateral method, the partner is not integrated.

Mini-Pill (Pearl-lndex 0.4-2.5):
The hormone progestogen slows down building of the membrane of the uterus, thus rendering the cervix membrane impermeable and keeping the ovary fixed.

Contrary to the pill ovulation is not prevented.

Rather safe.

 

Requires discipline. 2 hours of variance in taking it, reduceed reliability. Intermediate bleedings and spotting occur more often. Hormonal impairment.

Micro pill:
Works like the pill but is lower dosed.
 

Safety drops with lower doses.

Spiral (Pearl-lndex 1-3):
The spiral is implanted in the uterus. It is made of synthetics coiled with copper wire. Copper has an immobilising effect on sperms and acts as a foreign matter against which defensive cells are produced.

Depending on the type, a spiral lasts two to five years.

Rather safe.

 

Risk of inflammation and of tubal pregnancy. Painful implantation, regular gynaecological control. Not suitable for women who want to get pregnant later.

Condom (Pearl-lndex 2-5):
A condom consists of thin latex (rubber). It is soft and elastic and should be slipped on the penis before sexual intercourse

No side effects. Can be used at any time. Protects also against infections, such as e.g. Aids

Is considered disturbing and "separating". Requires absolute discipline during days of optimum fertilisation.

Diaphragm (Pearl-lndex 2-5):
It is a relatively large sized latex cap, to be inserted through the vagina and placed in front of the mouth of the womb.

 

Can be used spontaneously.

 

The cap has to be adapted individually and is inserted with a spermatocidal agent. Application has to be learned.

Chemical agents (Pearl-lndex 9-25):
Gel, cream, suppositories destroy the sperm coat by chemical agents thus rendering it infertile

 

Can be used spontaneously.

 

Has to be used some minutes before sexual intercourse. Occasional itching, rubor.

Not very safe.

 

Temperature Method in Connection with checking of cervical mucus (Pearl-lndex below 1):
Temperature is taken every morning before getting up. In addition, consistency of the mucus (produced inside the cervix) is checked with the finger at the orifice of the vagina.

 

No side effects, natural. Women learn much about their body.

Most reliable

 

Requires much discipline. A lot of application and evaluation rules to be observed. Requires experience to interpret the signs and curves correctly.

Sterilization:
of man or woman. Both cases require surgery that can hardly be undone.
   

Explanations :

Pearl-lndex:
Number of pregnancies occurring if this contraceptive was applied during one hundred cycles. The lower its value, the safer the contraceptive.

Method safety:
Experts differentiate between method safety and safety in practical life, which yields the variation range of the Pearl Index.

Environmental pollution:
Chemicals - contained in contraceptive - don't disappear without any traces or effects.


Traditional temperature method:

Problems of traditional natural contraception Solved by Lady-Comp and Baby-Comp
Temperature could be distorted by waking process Soft waking process
Measuring at the same time every day Measuring range 6 hours
Measuring errors can occur Measuring is monitored
Measuring variations due to geographical location Adapted measuring system
Measuring time 5 minutes Measuring time 30 seconds
Measuring precision 1/10 degree Measuring precision 1/100 degree
Reading error Value stored immediately
No values in comparison 700.000 evaluated cycles stored
Limited survey of measured values 5 years memory
Difficult evaluation by freak values Identifies freak values (disease, strain, etc.)
Pearl-Index 2 - 4 Pearl-Index 0.6
Ovulation hard to define Discerns next cycle optimum
Sex differentiation hardly possible Reliable prognosis regarding the child's sex
Manually Input of intercourse
Difficult to ascertain manually Early indication of pregnancy
Manually relatively inaccurate Calculation of date of confinement